Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 49
Filtrar
1.
Postepy Kardiol Interwencyjnej ; 20(1): 76-83, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38616934

RESUMO

Introduction: Aortic stenosis is the most common primary valve disease and requires invasive treatment. Transcatheter aortic valve implantation (TAVI) from a transfemoral access is a routine intervention worldwide. Aim: To investigate the correlation between external iliac artery diameter (EIAD) indexed to body surface area (BSA) (EIAD-BSA) and access site complications in patients undergoing TAVI via transfemoral access (TF) (TF-TAVI). Material and methods: Patients underwent TF-TAVI in 2017-2019 at the Upper-Silesian Medical Center in Katowice. Based on the preoperative multi-slice computed tomography (MSCT), pre-specified measurements of the ilio-femoral vessels were performed. The results were indexed to BSA and body mass index (BMI). Complications after TAVI were defined by Valve Academic Research Consortium 3 (VARC-3). The primary outcome regarding the adverse events after TAVI was the composite of access site complications requiring surgical intervention or blood transfusion. Results: The registry included 193 unselected patients with severe symptomatic aortic stenosis. Vascular and access-related complications including bleeding occurred in 17.1% of patients. Major TAVI access site complications (VARC-3) were reported in 5.7% of patients, while minor complications (VARC-3) occurred in 2.6%. EIAD-BSA demonstrated a positive correlation with the access site complications primary endpoint. Patients with greater EIAD-BSA had a numerically higher number of access site adverse events requiring surgical intervention or blood transfusion: n = 12 (5%) vs. n = 4 (4%), p = 0.011. Conclusions: External iliac artery diameter indexed to BSA could be an underestimated indicator of unfavorable outcomes after TF-TAVI, predicting periprocedural access site complications.

2.
J Cardiovasc Dev Dis ; 10(9)2023 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-37754828

RESUMO

Robots are defined as programmable machines that can perform specified tasks. Medical robots are emerging solutions in the field of cardiology leveraging recent technological innovations of control systems, sensors, actuators, and imaging modalities. Robotic platforms are successfully applied for percutaneous coronary intervention, invasive cardiac electrophysiology procedures as well as surgical operations including minimally invasive aortic and mitral valve repair, coronary artery bypass procedures, and structural heart diseases. Furthermore, machines are used as staff-assisting tools to support nurses with repetitive clinical duties i.e., food delivery. High precision and resolution allow for excellent maneuverability, enabling the performance of medical procedures in challenging anatomies that are difficult or impossible using conventional approaches. Moreover, robot-assisted techniques protect operators from occupational hazards, reducing exposure to ionizing radiation, and limiting risk of orthopedic injuries. Novel automatic systems provide advantages for patients, ensuring device stability with optimized utilization of fluoroscopy. The acceptance of robotic technology among healthcare providers as well as patients paves the way for widespread clinical application in the field of cardiovascular medicine. However, incorporation of robotic systems is associated with some disadvantages including high costs of installation and expensive disposable instrumentations, the need for large operating room space, and the necessity of dedicated training for operators due to the challenging learning curve of robotic-assisted interventional systems.

5.
J Invasive Cardiol ; 35(5): E279-E280, 2023 05.
Artigo em Inglês | MEDLINE | ID: mdl-37219856

RESUMO

Coronary artery ectasia is reported 1.2% up to 7.4% of patients. Giant coronary artery aneurysms are seen in 0.02% of patients. The best therapeutic approach is not yet defined. To our knowledge, this case report is the first to show 2 giant, partially thrombosed aneurysms of such enormous dimensions presenting as late ST-segment elevation infarction.


Assuntos
Aneurisma Coronário , Infarto Miocárdico de Parede Inferior , Infarto do Miocárdio com Supradesnível do Segmento ST , Doenças Vasculares , Humanos , Vasos Coronários
6.
J Clin Med ; 12(5)2023 Feb 24.
Artigo em Inglês | MEDLINE | ID: mdl-36902604

RESUMO

BACKGROUND: The two most common organisms found in infective endocarditis following transcatheter aortic valve implantation (TAVI-IE) are enterococci (EC-IE) and staphylococci (SC-IE). We aimed to compare clinical characteristics and outcomes of patients with EC-IE and SC-IE. METHODS: TAVI-IE patients from 2007 to 2021 were included in this analysis. The 1-year mortality was the primary outcome measure of this retrospective multi-center analysis. RESULTS: Out of 163 patients, 53 (32.5%) EC-IE and 69 (42.3%) SC-IE patients were included. Subjects were comparable with regard to age, sex, and clinically relevant baseline comorbidities. Symptoms at admission were not significantly different between groups, except for a lower risk for presenting with septic shock in EC-IE than SC-IE. Treatment was performed in 78% by antibiotics alone and in 22% of patients by surgery and antibiotics, with no significant differences between groups. The rate of any complication, in particular heart failure, renal failure, and septic shock during treatment for IE, was lower in EC-IE compared with SC-IE (p < 0.05). In-hospital (EC-IE: 36% vs. SC-IE: 56%, p = 0.035) and 1-year mortality (EC-IE: 51% vs. SC-IE: 70%, p = 0.009) were significantly lower in EC-IE compared with SC-IE. CONCLUSIONS: EC-IE, compared with SC-IE, was associated with a lower morbidity and mortality. However, absolute numbers are high, a finding that should trigger further research in appropriate perioperative antibiotic management and improvement of early IE diagnosis in the case of clinical suspicion.

7.
Kardiol Pol ; 81(4): 373-380, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36594529

RESUMO

BACKGROUND: The carotid artery is an alternative access route for transcatheter aortic valve implantation (TAVI), especially useful in patients unsuitable for traditional access routes including transfemoral (TF), subclavian, transapical, and aortic. AIMS: To investigate the feasibility and safety of transcarotid (TC) access for TAVI in comparison to the TF approach in a multicenter setting. METHODS: A total of 41 patients, treated between December 2014 and December 2018, were retrospectively reported to the Polish Registry of Common Carotid Artery Access for TAVI (POL-CAROTID). The median follow-up time was 619 (365-944) days, and Valve Academic Research Consortium-2 (VARC-2) definitions were applied. Clinical outcomes were compared with 41 propensity-matched TF-TAVI patients. RESULTS: The mean (standard deviation [SD]) patients' age was 78.0 (7.2) years, and 29 patients (70.7%) were men. Prohibitive iliofemoral anatomy and/or obesity (46.3%) and/or the presence of a stent graft in the abdominal aorta (31.7%) were the most common indications for TC-TAVI. Device success for TC-TAVI was comparable with the matched TF-TAVI group (90.2% vs. 95.3%, respectively, P = 0.396), and no periprocedural mortality was observed. Moreover, early safety was similar between the two groups (92.7% vs. 95.3%, respectively, log-rank P = 0.658) with only 1 case of non-disabling stroke during the first month after TC-TAVI. Consequently, no cerebrovascular events were observed in the mid-term, and the clinical efficacy of TC-TAVI corresponded well with TF-TAVI (90.2% vs. 92.7%, respectively, log-rank P = 0.716). A total of 4 (9.8%) deaths were noted in the TC-TAVI cohort in comparison to 3 (7.3%) in the TF-TAVI group. CONCLUSIONS: The results of the study indicated that the first cohort of Polish patients with implantations of second-generation transcarotid transcatheter heart valves had a similar prognosis to TF-TAVI with regard to safety and feasibility. TC access may be considered an optimal alternative for patients in whom the TF approach is precluded.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Masculino , Humanos , Idoso , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estenose da Valva Aórtica/cirurgia , Estudos Retrospectivos , Artérias Carótidas , Valva Aórtica/cirurgia , Resultado do Tratamento , Sistema de Registros
8.
Cardiol J ; 30(2): 188-195, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-34308536

RESUMO

BACKGROUND: The purpose of this study was to compare the safety and clinical outcomes of transcarotid (TC) and transapical access (TA) transcatheter aortic valve implantation (TAVI) patients whom the transfemoral approach (TF) was not feasible. METHODS: The analysis included consecutive patients with severe symptomatic aortic stenosis treated from 2017 to 2020 with TC-TAVI or TA-TAVI in two high-volume TAVI centers. The approach was selected by multidisciplinary heart teams after analyzing multislice computed tomography of the heart, aorta and peripheral arteries, transthoracic echocardiography and coronary angiography. RESULTS: One hundred and two patients were treated with alternative TAVI accesses (TC; n = 49 and TA; n = 53) in our centers. The groups were similar regarding age, gender, New York Heart Association class, and echocardiography parameters. Patients treated with TC-TAVI had significantly higher surgical risk. The procedural success rate was similar in both groups (TC-TAVI 98%; TA-TAVI 98.1%; p = 0.95). The rate of Valve Academic Research Consortium-2 defined clinical events was low in both groups. The percentage of new-onset rhythm disturbances and permanent pacemaker implantation was similar in TC and TA TAVI (4.1% vs. 11.3%; p = 0.17 and 10.2% vs. 5.7%; p = 0.39, respectively). In the TA-TAVI group, significantly more cases of pneumonia and blood transfusions were observed (11% vs. 0%; p = 0.01 and 30.2% vs. 12.2%; p = 0.03). The 30-day mortality was similar in TC and TA groups (4.1% vs. 5.7%; p = 0.71, respectively). CONCLUSIONS: Both TC and TA TAVI are safe procedures in appropriately selected patients and are associated with a low risk of complications.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Ecocardiografia , Contraindicações , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos
9.
Artigo em Inglês | MEDLINE | ID: mdl-36424214

RESUMO

OBJECTIVES: Transcatheter aortic valve implantation (TAVI) remains the preferred strategy for high-risk or elderly individuals with aortic valve (AV) stenosis who are not considered to be optimal surgical candidates. Recent evidence suggests that low-risk patients may benefit from TAVI as well. The current study evaluates midterm survival in low-risk patients undergoing elective surgical AV replacement (SAVR) versus TAVI. METHODS: The Aortic Valve Replacement in Elective Patients From the Aortic Valve Multicenter Registry (AVALON) compared isolated elective transfemoral TAVI or SAVR with sternotomy or minimally invasive approach in low-risk individuals performed between 2015 and 2019. Propensity score matching was conducted to determine SAVR controls for TAVI group in a 1-to-3 ratio with 0.2 caliper. RESULTS: A total of 2393 patients undergoing elective surgery (1765 SAVR and 629 TAVI) with median European System for Cardiac Operative Risk Evaluation II (EuroSCORE II) score 1.81 (interquartile range [IQR], 1.36 to 2.53]) were initially included. Median follow-up was 2.72 years (IQR, 1.32-4.08; max 6.0). Propensity score matching returned 329 TAVI cases and 593 SAVR controls. Thirty-day mortality was 11 out of 329 (3.32%) in TAVI and 18 out of 593 (3.03%) in SAVR (risk ratio, 1.10; 95% CI, 0.52-2.37; P = .801) groups, respectively. At 2 years, survival curves began to diverge in favor of SAVR, which was associated with 30% lower mortality (hazard ratio, 0.70; 95% CI, 0.496-0.997; P = .048). CONCLUSIONS: Our data did not demonstrate a survival difference between TAVI and SAVR during the first 2 postprocedure years. After that time, SAVR is associated with improved survival. Extended observations from randomized trials in low-risk patients undergoing elective surgery are warranted to confirm these findings and draw definitive conclusions.

10.
Postepy Kardiol Interwencyjnej ; 18(1): 14-26, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35982740

RESUMO

Introduction: Data regarding the duration of dual antiplatelet therapy (DAPT) in patients with drug-eluting stent restenosis (DES-ISR) treated with percutaneous coronary intervention (PCI) and drug-eluting balloons (DEB) or DES are not unambiguous. Aim: To evaluate the relationship between long-term outcomes and the length of DAPT in patients treated with PCI due to DES-ISR with DEB or DES. Material and methods: Overall, a total of 1,367 consecutive patients with DES-ISR, who underwent PCI with DEB or DES between 2008 and 2019 entered the study. The mean length of the follow-up was 1,298.7 ±794 days. We assessed study endpoints according to the duration of DAPT (≤ 3 vs. > 3 and ≤ 6 vs. > 6 months) before and after propensity score matching (PSM): stroke, target lesion revascularisation (TLR), target vessel revascularisation (TVR), myocardial infarction (MI), death and device oriented composite endpoints (DOCE). Kaplan-Meier estimates were created to differentiate long-term outcomes. Results: Pairwise contrast analysis considering type of PCI (DES vs. DEB) and duration of DAPT (≤ 6 vs. > 6 months) before PSM revealed superiority of DES + DAPT > 6 months vs. DEB + DAPT > 6 months for DOCE (p < 0.001), TVR (p = 0.02) and TLR (p = 0.01). Also, DES + DAPT ≤ 6 months was found to be superior compared to DEB + DAPT ≤ 6 months for DOCE (p < 0.001), TVR (p = 0.02) and TLR (p = 0.01). Kaplan-Meier estimate analysis confirmed that DAPT > 6 months is related to a higher stroke rate (p = 0.01) when compared to ≤ 6 months. Conclusions: Treatment with DAPT in patients with DES-ISR is related to better long-term outcomes in the case of PCI with DES than DEB. DAPT > 6 months is related to the greater rate of strokes, independently of the type of treatment (DES and DEB) than DAPT ≤ 6 months.

11.
Front Cardiovasc Med ; 9: 849971, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35615559

RESUMO

Background: Data regarding management of patients with unprotected left main coronary artery in-stent restenosis (LM-ISR) are scarce. Objectives: This study investigated the safety and effectiveness of percutaneous coronary intervention (PCI) vs. coronary artery bypass grafting (CABG) for the treatment of unprotected LM-ISR. Methods: Consecutive patients who underwent PCI or CABG for unprotected LM-ISR were enrolled. The primary endpoint was a composite of major adverse cardiac and cerebrovascular events (MACCE), defined as cardiac death, myocardial infarction (MI), target vessel revascularization (TVR), and stroke. Results: A total of 305 patients were enrolled, of which 203(66.6%) underwent PCI and 102(33.4%) underwent CABG. At 30-day follow-up, a lower risk of cardiac death was observed in the PCI group, compared with the CABG-treated group (2.1% vs. 7.1%, HR 3.48, 95%CI 1.01-11.8, p = 0.04). At a median of 3.5 years [interquartile range (IQR) 1.3-5.5] follow-up, MACCE occurred in 27.7% vs. 29.6% (HR 0.82, 95%CI 0.52-1.32, p = 0.43) in PCI- and CABG-treated patients, respectively. There were no significant differences between PCI and CABG in cardiac death (9.9% vs. 18.4%; HR 1.56, 95%CI 0.81-3.00, p = 0.18), MI (7.9% vs. 5.1%, HR 0.44, 95%CI 0.15-1.27, p = 0.13), or stroke (2.1% vs. 4.1%, HR 1.79, 95%CI 0.45-7.16, p = 0.41). TVR was more frequently needed in the PCI group (15.2% vs. 6.1%, HR 0.35, 95%CI 0.15-0.85, p = 0.02). Conclusions: This analysis of patients with LM-ISR revealed a lower incidence of cardiac death in PCI compared with CABG in short-term follow-up. During the long-term follow-up, no differences in MACCE were observed, but patients treated with CABG less often required TVR. Visual overview: A visual overview is available for this article. Registration: https://www.clinicaltrials.gov; Unique identifier: NCT04968977.

12.
Kardiol Pol ; 80(7-8): 765-773, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35445739

RESUMO

BACKGROUND: There is limited data on the optimal revascularization strategy in patients with recurrent in-stent restenosis (R-ISR). AIMS: To compare the long-term outcomes of patients treated with either a thin-strut drug-eluting stent (thin-DES) or a drug-eluting balloon (DEB) for R-ISR in a drug-eluting stent (DES). METHODS: A multicenter DEB-DRAGON registry was used to retrospectively identify patients with R-ISR who received either a thin-DES or a DEB. Propensity score matching was applied to adjust for baseline differences. The primary outcome was target lesion revascularization (TLR). RESULTS: Out of 311 patients (mean age, 67 years; 63% male) with R-ISR, 86 (27.7%) were treated with a thin-DES and 225 (72.3%) with a DEB. Median follow-up was 2.6 years. TLR occurred in 18 (20.9%) patients who received thin-DES and 61 (27.1%) patients treated with DEB (hazard ratio [HR], 0.57; 95% confidence interval [CI], 0.33-0.98; log-rank P = 0.04). The difference remained significant in a propensity score-matched cohort of 57 patients treated with thin-DES and 57 patients treated with a DEB (17.5 vs. 33.3%, respectively; HR, 0.38; 95% CI, 0.17-0.86; P = 0.01). The risks of device-oriented adverse cardiac events and all-cause mortality were similar after thin-DES or DEB in both unadjusted and propensity score-matched cohorts. In a multivariable Cox proportional hazard model, the treatment with a thin-DES was an independent predictor of a TLR-free survival (HR, 0.33; 95% CI 0.13-0.84; P = 0.02). CONCLUSIONS: In patients with R-ISR implantation of a thin-DES is associated with a lower risk of repeated revascularization compared with angioplasty with a DEB.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária , Stents Farmacológicos , Intervenção Coronária Percutânea , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Cateteres Cardíacos , Materiais Revestidos Biocompatíveis , Reestenose Coronária/etiologia , Reestenose Coronária/cirurgia , Stents Farmacológicos/efeitos adversos , Feminino , Humanos , Masculino , Intervenção Coronária Percutânea/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Resultado do Tratamento
14.
J Card Surg ; 37(3): 526-531, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34821415

RESUMO

BACKGROUND: The incompetent bicuspid aortic valve (BAV) can be repaired using various techniques. This study presents a prospective comparison of external and subcommissural aortic annuloplasty. METHODS: Fifty consecutive patients (38 males, age: 43.9 ± 15.8 years) with BAV insufficiency with or without aortic dilatation underwent valve repair in a single institution. They were prospectively allocated to one of two groups based on the aortic annulus stabilization technique: 25 patients were operated on using the subcommissural annuloplasty (SCA) and 25 using the external complete annuloplasty (EA). Transthoracic echocardiography was performed in all patients before the operation and 1 and 3 years after the operation. Moreover, mortality and morbidity at 7 years were evaluated. RESULTS: In prospective echocardiographic comparison, EA was associated with smaller diameter of the aortic annulus (24.1 ± 2.6 mm vs. 25.8±2.1 mm, p < .05) and lower mean and peak transvalvular gradients (7 ± 4 mmHg vs. 13 ± 4 mmHg, p = .02 and 15.3 ± 9.7 mmHg vs. 20.7 ± 5.6 mmHg, p = .03, respectively). No patients died or required reoperation due to recurrent insufficiency at 6,81 (interquartile range-0,17) years after the operation. The Kaplan-Meier actuarial freedom from aortic regurgitation (AR) grade =2 or gradient > 20 mmHg at 35.1 ± 3.6 months years was 96% (24 out of 25) for patients who had external annuloplasty and amounted to 76% (19 out of 25) for those who had SCA, p = .05). CONCLUSIONS: External annuloplasty performed during repair of the BAV is associated with better hemodynamics at medium-term follow-up compared to SCA.


Assuntos
Insuficiência da Valva Aórtica , Doença da Válvula Aórtica Bicúspide , Anuloplastia da Valva Cardíaca , Adulto , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/cirurgia , Ecocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Estudos Retrospectivos , Resultado do Tratamento
15.
Pol Arch Intern Med ; 132(2)2022 02 28.
Artigo em Inglês | MEDLINE | ID: mdl-34845900

RESUMO

INTRODUCTION: Transcatheter aortic valve­in ­valve implantation (ViV­TAVI) has emerged as an alternative to redo surgery in patients with failed surgical aortic bioprosthesis. OBJECTIVES: We evaluated the safety and efficacy of ViV­TAVI in Polish patients after surgical aortic valve replacement. PATIENTS AND METHODS: This was a nationwide multicenter registry of ViV­TAVI procedures. Data were collected using an online form, and the clinical follow ­up lasted 1 year. RESULTS: From 2008 to 2020, 130 ViV­TAVI procedures were performed (1.9% of all transcatheter aortic valve implantation [TAVI] cases). A considerable increase in ViV­TAVI procedures since 2018 has been observed (n = 59, 45% of ViV­TAVI cases). Hancock II, Freestyle, and homograft were the most frequently treated bioprostheses. The self ­expanding supra ­annular Corevalve / Evolut valve was used in 76% of cases. In 21% of cases, the mean postprocedural pressure gradient (PG) exceeded 20 mm Hg. All­cause mortal­ity at 1 year was 10.8%. Aortic valve stenosis was associated with a higher mean PG than aortic valve regurgitation or mixed disease (P = 0.004). Supra ­annular transcatheter aortic valves were associated with lower mean PGs than intra ­annular valves (P = 0.004). Second ­generation devices were associated with shorter procedure time (120 min vs 135 min, P = 0.04), less frequent need for additional TAVI (2% vs 10%, P = 0.04), and lower 1­year cardiovascular mortality (95% vs 82.8%, P = 0.03) than first­generation valves. CONCLUSIONS: Transcatheter treatment of failed bioprostheses is increasingly common, with the best hemodynamic effect shown for supra ­annular valves. The introduction of second­generation valves has improved procedural and clinical outcomes.


Assuntos
Bioprótese , Substituição da Valva Aórtica Transcateter , Valva Aórtica/cirurgia , Humanos , Polônia , Desenho de Prótese , Sistema de Registros , Resultado do Tratamento
16.
Postepy Kardiol Interwencyjnej ; 17(3): 281-289, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34819964

RESUMO

INTRODUCTION: Cell therapy has the potential to improve symptoms and clinical outcomes in refractory angina (RFA). Further analyses are needed to evaluate factors influencing its therapeutic effectiveness. AIM: Assessment of electromechanical (EM) parameters of the left ventricle (LV) and investigation of correlation between EM parameters of the myocardium and response to CD133+ cell therapy. MATERIAL AND METHODS: Thirty patients with RFA (16 active and 14 placebo individuals) enrolled in the REGENT-VSEL trial underwent EM evaluation of the LV with intracardiac mapping system. The following parameters were analyzed: unipolar voltage (UV), bipolar voltage (BV), local linear shortening (LLS). Myocardial ischemia was evaluated with single-photon emission computed tomography (SPECT). The median value of each EM parameter was used for intra-group comparisons. RESULTS: Global EM parameters (UV, BV, LLS) of LV in active and placebo groups were 11.28 mV, 3.58 mV, 11.12%, respectively; 13.00 mV, 3.81 mV, 11.32%, respectively. EM characteristics analyzed at global and segmental levels did not predict response to CD133+ cell therapy in patients with RFA (Global UV, BV and LLS at rest R = -0.06; R = 0.2; R = -0.1 and at stress: R = 0.07, R = 0.09, R = -0.1, respectively; Segmental UV, BV, LLS at rest R = -0.2, R = 0.03, R = -0.4 and at stress R = 0.02, R = 0.2, R = -0.2, respectively). Multiple linear regression of the treated segments showed that only pre-injection SPECT levels were significantly correlated with post-injection SPECT, either at rest or stress (p < 0.05). CONCLUSIONS: Electromechanical characteristics of the left ventricle do not predict changes of myocardial perfusion by SPECT after cell therapy. Baseline SPECT results are only predictors of changes of myocardial ischemia observed at 4-month follow-up.

17.
J Clin Med ; 10(22)2021 Nov 21.
Artigo em Inglês | MEDLINE | ID: mdl-34830722

RESUMO

Data on the clinical outcomes comparing synthetic fluorocarbon polymer polytetrafluoroethylene- (PTFE, GraftMaster) and polyurethane- (Papyrus) covered stents (CSs) to seal coronary artery perforations (CAPs) are limited. We aimed to evaluate 30-day and 1-year clinical outcomes after PCI complicated by CAP and treated with CS. We assessed 106 consecutive patients with successful CAP sealing (122 CSs): GraftMaster (51 patients, 57 CSs) or Papyrus CS (55 patients, 65 CSs). The primary endpoint was the occurrence of major adverse cardiac events (MACE), defined as the composite of cardiac death, target lesion revascularisation (TLR), and myocardial infarction (MI). The mean age of subjects was 69 ± 9.6 years (53.8% males). No significant differences were identified between the GraftMaster and Papyrus groups at the 30-day follow-up for MACE, cardiac death, MI and stent thrombosis (ST), while significantly lower rate of TLR and TVR (p = 0.02) were confirmed in the Papyrus group. At one year, differences remained similar between stents for MACE, a trend towards a lower rate of TLR (p = 0.07), MI (p = 0.08), and ST (p = 0.08), and higher for cardiac death (p = 0.07) was observed in the Papyrus group. This real-life registry of CAP illustrated that the use of Papyrus CS is associated with lower rates of TLR and TVR at 30-day follow-up in comparison to the GraftMaster CSs and no significant differences between both assessed CS at one year of follow-up.

18.
Kardiochir Torakochirurgia Pol ; 18(3): 159-164, 2021 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-34703473

RESUMO

INTRODUCTION: Open aortic arch surgery is a complex cardiac surgical procedure. AIM: We reviewed the 10-year outcomes of elective aortic arch aneurysm surgery in a single cardiac surgical center. MATERIAL AND METHODS: The analysis includes all patients who underwent elective aortic arch surgery at our institution between January 2010 and December 2020. The study population was divided into group A consisting of patients operated on during the first 5 years, and group B, including patients operated on during the subsequent 5 years. The groups were compared with regard to baseline characteristics, scope of the surgery, operative and postoperative data as well as morbidity and mortality. RESULTS: Eighty-six elective aortic arch procedures were performed during the analyzed period, including 25 (29%) patients in group A and 61 (71%) patients in group B. The hemiarch procedure was more frequently performed in group A (17 patients, 68%) in comparison to group B (21 patients, 34%) (p = 0.008). Stroke was recorded in 6 (20%) patients from group A and 5 (8.2%) patients from group B (p = 0.002). Five-year survival was 60 ±9.8% for group A, and 81 ±6.2% for group B (log-rank test, p = 0.003). CONCLUSIONS: After completion of the learning curve, open aortic arch surgery is associated with acceptable early mortality, low incidence of stroke, and a high 5-year survival rate.

19.
Artigo em Inglês | MEDLINE | ID: mdl-34682351

RESUMO

Core temperature reflects the temperature of the internal organs. Proper temperature measurement is essential to diagnose and treat temperature impairment in patients. However, an accurate approach has yet to be established. Depending on the method used, the obtained values may vary and differ from the actual core temperature. There is an ongoing debate regarding the most appropriate anatomical site for core temperature measurement. Although the measurement of body core temperature through a pulmonary artery catheter is commonly cited as the gold standard, the esophageal temperature measurement appears to be a reasonable and functional alternative in the clinical setting. This article provides an integrative review of invasive and noninvasive body temperature measurements and their relations to core temperature.


Assuntos
Temperatura Corporal , Projetos de Pesquisa , Humanos , Temperatura
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...